[rev_slider home] tagline2

Need Your A/C Fixed TODAY? 561 331 0504

  • This field is for validation purposes and should be left unchanged.

Checking for Freon Leak West Palm Beach

An upstream air conditioning evaporator curl is ordinarily found over a gas furnace. Your curl might be housed in its own particular metal bureau called a Cased Coil or you may have a loop set within a metal or fiberboard supply plenum. To discover the curl you should expel the bureau screws in the event that it is a cased loop or you may need to cut into the plenum with sheet metal cutters at times. If it’s not too much trouble before cautioned that if cutting into a sheet metal plenum extraordinary care must be utilized so as NOT to cut into any refrigerant copper lines as there is generally to a great degree high freon weights in these lines. On the off chance that you will endeavor this dependably wear defensive eyewear and gloves as freon in the eye will consume the eye PERMANENTLY! Numerous have the misinterpretation that freon solidifies. The exact inverse is valid. On the off chance that you let freon leak out on the ground (an E.P.A. infringement) it would bubble even at a temperature of around 40 degrees underneath zero! In the event that uncertain of yourself, if it’s not too much trouble call a qualified HVAC Company to do this work.


Free, No-Obligation Repair Estimate! CLICK HERE for offer

[/fusion_builder_column]

Checking for freon leaks includes being certain there is some freon in the system or you will have no strain to finish the check. This is finished by painting a solid nonbasic arrangement made for this reason (don’t utilize family products as they are destructive eventually) on all joints of copper, fittings, slim tubes, tubing twists, metering gadgets or T.X.V. (Warm Expansion Valve), strainers, channels, dryers or some other associations. The refrigerant lines that keep running from the evaporator curl to the outside unit are checked in a similar way. Make certain to check the little fine tubes that are secured with a black bit of refrigerant line set protection. Vibration throughout the years frequently make leaks at these tubes – on the off chance that they are leaking a VERY talented administration expert MAY have the capacity to seal the leak yet, as a rule, it is the ideal opportunity for another loop. All the tube twists at BOTH closures of the curl should be checked (on the off chance that you can get to them). The metering gadget or TXV additionally should be “checked”. On the off chance that utilizing the leak arrangement, paint it on generously and observe VERY intently for any air pockets regardless of how little they may appear. Any air pocket is a leak and should be repaired.

Our customers are why we are the BEST AC Company in West Palm Beach! Heres what they say about us!

5 star rating on yelp
ac west palm beach excellent service
Call today for your FREE service call!: 561.331.0504
We are eager to show you why we have been rated the #1 Air Conditioning company in West Palm Beach.
Dial Now 561.331.0504.

Commercial AC Services West Palm Beach

In addition to residential air conditioning repair, installation, duct cleaning and dryer vent cleaning, we also specialize in commercial air conditioning services in the West Palm Beach area.